KU UP 114 B
X-Band Up Converter
13750 ... 14500 MHz
This device converts the IF frequency range 950 ... 1700 MHz up to the frequency range 13750 ... 14500 MHz. Typical applications are MMDS transmitter as well as DVB-T or DVB-S systems. The up converter includes band pass filters for high spurious rejection and a high quality VCO with low phase noise and therefore it is suitable for all modulation types. Together with a power amplifier a higher power output can be achieved.
Preliminary data!
| Specifications | ||
| Type | KU UP 114 B | |
| Input frequency range (IF) | 950 ... 1700 MHz | |
| IF input power | max. +7 dBm / 5 mW | |
| Output frequency range (RF) | 13750 MHz ... 14500 MHz | |
| Output power P1dB | typ. 200 mW (+23 dBm) | |
| Output power (digital applications) | typ. 25 ... 50 mW | |
| Gain | typ. 22 dB | |
| Image rejection | typ. 80 dB | |
| LO frequency | 12800 MHz | |
| LO accuracy @ 18 °C | +/- 2 ppm | |
| LO frequency stability (0 ... 40 °C) | +/- 3 ppm | |
| Phase noise | ||
| @ 1 kHz | typ. -75 dBc/Hz | |
| @ 10 kHz | typ. -79 dBc/Hz | |
| @ 100 kHz | typ. -105 dBc/Hz | |
| Supply voltage | +12 ... 14 V DC | |
| Current consumption | typ. 850 mA | |
| Reference frequency input | 10 MHz / 2 ... 10 mW | |
| Reference input connector / impedance | SMA-female, 50 ohms | |
| Input connector / impedance | SMA-female, 50 ohms | |
| Output connector / impedance | SMA-female, 50 ohms | |
| Maximum case temperature | +55 °C | |
| Dimensions (mm) | 126 x 64 x 22 | |
| Case | milled aluminium | |
| Weight | typ. 310 g | |
Features
- Low phase noise oscillator
- High frequency stability of the oscillator
- Additional input for 10 MHz reference frequency
- Automatic activation of PLL if external 10 MHz signal is supplied
- High linearity
- Overvoltage protection and reverse polarity protection
Applications
- Digital broadcast systems (DVB-T, DVB-S)
- Analog and digital transmission systems
Important note
- Additional cooling required
- Specifications subject to change without notice -