SP 500 W 48

Power Supply Unit

Specifications

Type

SP 500 W 48

INPUT

AC input voltage range

88 ... 264 V AC

DC input voltage range

124 ... 370 V DC

Frequency range

47 ... 63 Hz

AC input current (at 230 V)

3.5 A

AC inrush current (at 230 V)

36 A

Efficiency

87 %

OUTPUT

DC voltage

48 V

Voltage adjust range

41 ... 56 V

Voltage tolerance

+/- 1.0 %

Ripple and noise

max. 300 mVpp

Rated current

10 A

Current range

0 ... 10 A

Rated power

480 W

Setup time, rise time

1500 ms, 50 ms at full load (at 230 V AC)

Hold time (typ.)

24 ms at full load (at 230 V AC)

PROTECTION

Over voltage

57.6 ... 67.2 V (Protection type: Hiccup mode, recovers automatically after fault condition is removed)

Withstand voltage

I/P-O/P: 3.0 kV AC

I/P-F/G: 1.5 kV AC

O/P-FG: 0.5 kV AC

Dimensions (mm)

170 x 120 x 93

I/P = Eingang (Input), O/P = Ausgang (Output),
FG = Masseanschluss, I/P = Eingang (Input), O/P = Ausgang (Output),
FG = Masseanschluss (Ground)

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • Built-in remote ON-OFF control
  • Forced air cooling by built-in DC fan
  • Protections:Short circuit/Over load/Over voltage/Over temperature

Dimensions

Save product

- Specifications subject to change without notice -