RSP 2400 W 48
Power Supply Unit
| Specifications | |
| Type | RSP 2400 W 48 |
| INPUT | |
| AC input voltage range | 180 ... 264 V AC |
| (47-63 Hz) | |
| 254 ... 370 V DC | |
| AC input current (at 230 V) | 12 A |
| AC inrush current (at 230 V) | 60 A |
| Efficiency | 91.5 % |
| OUTPUT | |
| DC voltage | 48 V |
| Voltage adjust range | 43 ... 56 V |
| Voltage tolerance | +/- 1.0 % |
| Ripple and noise | max. 200 mVpp |
| Rated current | 50 A |
| Current range | 0 ... 50 A |
| Rated power | 2400 W |
| Setup time, rise time | 1000 ms, 80 ms at full load (at 230 V AC) |
| Hold time (typ.) | 12 ms at full load (at 230 V AC) |
| PROTECTION | |
| Over voltage | 57.6 ... 67.2 V (Protection type: Shut down o/p voltage, repower on to recover) |
| Withstand voltage | I/P-O/P: 3.0 kV AC |
| I/P-F/G: 1.5 kV AC | |
| O/P-FG: 0.5 kV AC | |
| Dimensions (mm) | 278 x 177.8 x 63.5 |
| I/P = Eingang (Input), O/P = Ausgang (Output), FG = Masseanschluss, I/P = Eingang (Input), O/P = Ausgang (Output), FG = Masseanschluss (Ground) | |
Features
- AC input active surge current limiting
- Built-in active PFC function,PF>0.95
- Forced air cooling by built-in DC with fan speed control function
- High efficiency
- Built-in remote sense function
- Built-in 12V/0.1A auxiliary output for remote control
- Built-in remote ON-OFF control
- Protections: Short circuit / Overload / Over voltage / Over temperature / Fan alarm
Dimensions
- Specifications subject to change without notice -