MKU PA 34350 CU

Linear Power Amplifier

3400 ... 3460 MHz • 350 W

This new power amplifier, which is based on LD MOS technology, is characterized by high linearity and best performance. The amplifier module is thermally very stable. Due to the high linearity, it can be used for all operating modes, like SSB, CW or DATV (digital amateurtelevision) or other digital modes. In contrast to conventional tube amplifiers, no high voltage transformers and other dangerous components are needed
Thepower amplifier can also be used within professional applications like digital video broadcast (DVB) or other communication systems using COFDM and digital modulation.

Specifications

Type

MKU PA 34350 CU

Frequency range

3400 ... 3460 MHz

Input power

typ. 1.0 W, max. 1.2 W

Output power P1dB

min. 300 W (CW)

Saturation power

min. 350 W (CW)
typ. 370 W (CW)

Small signal gain

min. 28 dB

Gain flatness

max. +/- 0.4 dB

Harmonic rejection @ 350 W

40 dB

IM3 @ 100 W PEP

min. -40 dBc

Efficiency @ 350 W (CW)

typ. 34 %

Input return loss (S11)

min. 10 dB

VSWR of load

max. 1.8:1

Maximum case temperature

+55 °C

Supply voltage

+28 V DC

Current consumption

max. 42 A

Quiescent current

typ. 4.5 A

Input connector / impedance

SMA-female, 50 ohms

Output connector / impedance

N-female, 50 ohms

Case

milled aluminium, silver-plated

Dimensions (mm)

190 x 152 x 38.5

Weight

typ. 4800 g

Features

  • Monitor output for forward power detection (DC voltage)
  • High gain and output power
  • Milled copper case, silver plated
  • Built-in sequence control
  • Incl. hight-temperature-protection
  • Output for TX-LED
  • Output for driving an antenna relay

Applications

  • Analog and digital transmission systems

Options

  • Amplifier mounted on heat sink with fans
  • Other frequencies on request

Accessories

As an alternative to our high power heat sinks we can offer a liquid cool plate.

You will find further information for dimensioning heat sinks under the rubric heat sinks.

1) Dimensioned for 25 °C ambient temperature

Important note

  • Module does not contain coaxial relay!

Save product