Linear Power Amplifier
3400 ... 3460 MHz • 350 W
This new power amplifier, which is based on LD MOS technology, is characterized by high linearity and best performance. The amplifier module is thermally very stable. Due to the high linearity, it can be used for all operating modes, like SSB, CW or DATV (digital amateurtelevision) or other digital modes. In contrast to conventional tube amplifiers, no high voltage transformers and other dangerous components are needed
Thepower amplifier can also be used within professional applications like digital video broadcast (DVB) or other communication systems using COFDM and digital modulation.
Specifications | |
Type | MKU PA 34350 CU |
Frequency range | 3400 ... 3460 MHz |
Input power | typ. 1.0 W, max. 1.2 W |
Output power P1dB | min. 300 W (CW) |
Saturation power | min. 350 W (CW) |
Small signal gain | min. 28 dB |
Gain flatness | max. +/- 0.4 dB |
Harmonic rejection @ 350 W | 40 dB |
IM3 @ 100 W PEP | min. -40 dBc |
Efficiency @ 350 W (CW) | typ. 34 % |
Input return loss (S11) | min. 10 dB |
VSWR of load | max. 1.8:1 |
Maximum case temperature | +55 °C |
Supply voltage | +28 V DC |
Current consumption | max. 42 A |
Quiescent current | typ. 4.5 A |
Input connector / impedance | SMA-female, 50 ohms |
Output connector / impedance | N-female, 50 ohms |
Case | milled aluminium, silver-plated |
Dimensions (mm) | 190 x 152 x 38.5 |
Weight | typ. 4800 g |
Features
- Monitor output for forward power detection (DC voltage)
- High gain and output power
- Milled copper case, silver plated
- Built-in sequence control
- Incl. hight-temperature-protection
- Output for TX-LED
- Output for driving an antenna relay
Applications
- Analog and digital transmission systems
Options

- Amplifier mounted on heat sink with fans
- Other frequencies on request
Accessories
- Recommended power supply: RSP 1500-27
- Recommended heat sink: SK 320 - 240 1)
- Recommended fan: 3 pieces FAN 80x80 HP 24 V 1)
- Recommended heat-conductive paste: Arctic Silver 5
As an alternative to our high power heat sinks we can offer a liquid cool plate.
You will find further information for dimensioning heat sinks under the rubric heat sinks.
1) Dimensioned for 25 °C ambient temperature
Important note
- Module does not contain coaxial relay!