MKU PA 13250 CU

High Power Amplifier for 1.3 GHz

1270 ... 1300 MHz • 250 W

This linear high power amplifier was developed for producing high frequency energy for accelerators applications.

High power, high efficiency and best linearity are achieved by our high power amplifier for the 23 cm amateur radio band. Compared to tube power amplifiers the used LDMOS transistor operates with a supply voltage of only +50 V DC. High voltage transformers, waiting for tube warm-up and retuning of the tube are the past! The power amplifier can be mounted close to the antenna to avoid power losses caused by long coaxial cable.

Specifications

Type

MKU PA 13250 CU

Frequency range

1270 ... 1300 MHz

Input power

4 ... 6 W

Max. input power

6 W

Output power P1dB

typ. 250 W

Saturation power

typ. 300 W

Small signal gain

min. 17 dB

Gain flatness

max. +/- 1 dB

Harmonic rejection

min. 35 dB @ 250 W

IM3 @ 200 W PEP

-40 dBc

Efficiency

typ. 50 % @ 250 W

ON voltage

+9 ... 14 V DC (ON)

Input return loss (S11)

typ. 10 dB

VSWR of load

max. 1.8:1

Maximum case temperature

+65 °C

Supply voltage

+50 V DC

Current consumption

max. 12 A @ 300 W (CW)

Quiescent current

typ. 0.25 A

Input connector / impedance

SMA-female, 50 ohms

Output connector / impedance

N-female, 50 ohms

Case

milled copper, silver-plated

Dimensions (mm)

130 x 59 x 20

Weight

typ. 730 g

Features

  • Milled copper case to provide optimum heat transfer
  • 50 V LD MOSFET technology
  • High linearity
  • High efficiency (up to 50 %)
  • Overvoltage protection and reverse polarity protection
  • Monitor output for forward power detection (DC voltage)
  • ON / OFF control with DC voltage

Applications

  • Research: High Power Amplifier for accelerators
  • Analog and digital (COFDM) transmission systems
  • Amateur Radio operations (EME, contest)

Options

  • Amplifier mounted on heat sink with fans
  • Amplifier installed into 19" rackmount case
  • High linear version "Class A" on request

Accessories

You will find further information for dimensioning heat sinks under the rubric heat sinks.

1) Dimensioned for 25 °C ambient temperature

Save product

- Specifications subject to change without notice -