KU PA 2325 DLK
Power Amplifier
2300 ... 2450 MHz • 50 W
Specifications | |
Type | KU PA 2325 DLK |
Frequency range | 2300 ... 2450 MHz |
Input power | typ. 5 W |
Output power P1dB | typ. 40 W |
Saturation power | 50 ... 60 W (CW) |
Gain | typ. 10 dB |
IM3 @ 15 W PEP | typ. -40 dBc |
ON voltage | +5 ... 14 V DC (ON) |
VSWR of load | max. 1.8:1 |
Maximum case temperature | +55 °C |
Supply voltage | +13 V DC |
Current consumption | typ. 10 A |
Input connector / impedance | SMA-female, 50 ohms |
Output connector / impedance | SMA-female, 50 ohms |
Case | milled aluminium |
Dimensions (mm) | 130 x 60 x 20 |
Weight | typ. 250 g |
Features
- Overheat protection
- Overvoltage protection and reverse polarity protection
- Monitor output for forward power detection (DC voltage)
- ON / OFF control with DC voltage
Applications
- Multichannel Multipoint Distribution Service (MMDS)
- Analog and digital transmission systems
- Especially usable for DATV
Options

- Amplifier mounted on heat sink with fans
Accessories
- Recommended power supply: SP 200 W 12
- Recommended heat sink: SK 150 - 62 1)
- Recommended fan: FAN 60x60 HP 12 V 1)
Alternative 1:
- Recommended heat sink: SK 200 - 80 1)
- Recommended fan: FAN 80x80 12 V 1)
Alternative 2:
- Recommended heat sink: SK 300 - 62 1)
- Recommended fan: FAN 60x60 12 V 1)
- Thermal cut-out thermostat TS-65/10
You will find further information for dimensioning heat sinks under the rubric heat sinks.
1) Dimensioned for 25 °C ambient temperature
Important note
- Module does not contain coaxial relay!
- Specifications subject to change without notice -